Camplas

Water Tanks

Whether you need a cold water storage tank or a hot water system, Camplas Technology provides versatile GRP tank solutions tailored to your requirements. Our tanks are available in capacities from 30,000 liters to 100 cubic meters and can be customized with multiple flange connections. Additionally, they come in translucent finishes or a selection of standard colors. If required, we can construct tanks from WRAS-approved materials to meet stringent water quality and safety standards. Rely on Camplas for high-quality, adaptable water storage solutions suitable for a broad range of applications.

70m3 tank water tank equipped with Type air AB airgap - Kingfisher Direct
60 cubic metre tanks - Demineralised water- Dungeness B Nuclear Power station
l 2 x 60m3 and 1 x 40m3 - Maxol- Adblue tanks
4x 100m3 Anearobic digestate tanks
60m3 Water tank
Customised stock tanks - 30m3 Water storage tank
100m3 cube tank Storing Demineralised water For Yara International

Water Storage Tanks

Downloads

Click on the link below to download the customised storage tank’s data sheet

15,000 tanks now in service installed worldwide

Fully customisable

BS4994-1987(formerly BS4994-1973) with a minimum factor of safety of 8/1

Customisable in 30, 40, 50,60,80,100 cubic metre capacity

You can rotate, zoom in and turn the tank to see all of its features

Camplas water tanks are built to the same high standards as our standard tanks but can be customised with multi flange connections, fitted with roof manways and access ladders. A range of standard colours added externally to reduce UV penetration and for aesthetic reasons.

Customisable Options

Any RAL colour is available

– some examples are shown below:

Originally designed for tanker deliveries of UAN (Ureic Ammonium Nitrate) liquid fertilisers but have now become ‘The Standard’ bulk storage tank for many chemicals in the range up to 100m³.

 

Camplas’s Helically wound GRP tanks have a 20 times higher tensile strength than Polyethylene and do not suffer from the phenomena known as

environmental stress cracking which can cause

catastrophic failure.

2 x100m3 tanks delivered to Immingham on Behalf of Yara

Key features of the Our Water Storage Tanks

50pn16 – 450pn16 flanges

Can be made in any RAL colour

Ladders and handrail options available

Hinged Roof Manways
(water tanks)

Gallery

Select image to enlarge

FAQs

Frequently asked questions about Water Tanks

Can’t find the answer you need? Our technical team will advise on your application.

Camplas manufactures GRP water tanks in capacities from 30 to 300 cubic metres (30,000 to 300,000 litres). Vertical tanks are supplied up to 200 cubic metres; larger capacities are manufactured in a horizontal configuration. Potable and customised water tanks are built to order, so the capacity, dimensions and connections can be matched to the application and the space available.

Yes. Standard Storage Tanks for non-potable duties, including rainwater harvesting, process water and waste water, are available from stock. However, as standard tanks have a fixed nozzle arrangement, a customised tank is generally better suited to most water storage installations, allowing inlet, outlet and overflow connections to be positioned to match the site pipework.

Potable water tanks are manufactured to order to comply with the Water Supply (Water Fittings) Regulations 1999. All materials in contact with the stored water are WRAS-approved to BS 6920, and tanks for above-ground installation are given an opaque finish to prevent light transmission and algal growth. Nozzle positions, fittings and access arrangements are specified to the installation at enquiry stage.

Potable water storage is subject to the Water Supply (Water Fittings) Regulations 1999, which do not apply to tanks for non-potable duties. A compliant potable water tank requires:

  • WRAS-approved materials. All materials in contact with the stored water should be WRAS-approved to BS 6920, demonstrating that they do not affect the taste, odour, appearance or quality of the water.
  • Inlet control and backflow prevention. The supply must be fitted with a float-operated valve to shut off the inflow and a servicing valve for maintenance, and the inlet must be protected against backflow into the mains supply, typically by means of a Type AB air gap.
  • Exclusion of light and contamination. Above-ground tanks must have an opaque shell to prevent light transmission and algal growth; below-ground tanks are shielded from daylight by the surrounding ground. In both cases the tank must have a close-fitting cover that is not airtight, with a screened vent to prevent the ingress of insects and debris, and below-ground tanks must also be sealed against groundwater ingress.
  • Warning pipe and overflow. A screened overflow must be provided, sized to prevent the tank overfilling, and must discharge to a point where it will be readily noticed.
  • Thermal protection. The tank must be protected against freezing and installed so that stored water is kept cool; cold water should be maintained below 20°C to control the risk of legionella.
  • Circulation. Inlet and outlet connections must be positioned so that water moves through the whole tank, preventing stagnation in dead zones.
  • Access for inspection and cleaning. A manway must be provided so that the tank can be inspected, cleaned and disinfected periodically.

Camplas potable water tanks are manufactured from WRAS-approved materials with a 600 mm access manway as standard and an opaque finish for above-ground installation, and can be supplied with a Type AB air gap ball valve assembly, insulation, and connections positioned to suit the installation.

Potable duty should be specified at enquiry stage so that the tank is manufactured to the correct specification.

Both are manufactured from GRP, but to different specifications. A potable (drinking) water tank is designed to protect water quality: it is built from WRAS-approved materials, given an opaque finish where installed above ground, and fitted with backflow protection on the inlet.

A waste water or sewage tank is designed to contain an aggressive liquid: it has a dished base and sump for complete sludge removal, decant valves to draw off liquor, and options such as odour control vents and double-skin construction with leak detection.

Camplas manufactures both, and the specification is confirmed for each application at the quotation stage.

A 600 mm side manway with a bolted cover is fitted as standard. Options include a hinged roof manway, a ladder with safety cage, handrails, an acrylic viewing port, a ball valve assembly with Type AB air gap, a butterfly valve, and additional flanged connections positioned to suit your pipework.

For sites where freezing is a risk, Camplas manufactures insulated water tanks, which incorporate 50 mm rigid polyurethane foam between filament-wound GRP skins to reduce heat loss and protect the contents from freezing. Insulated tanks are designed as bespoke units, so please contact us with your site details.

Contact us about Water Tanks

Your email was sent successful.

Thank you for getting in touch! 

We appreciate you contacting Camplas.

One of our colleagues will get back in touch with you soon!